top of page
Update to new license module
A handy tool for hydrogeologist, water engineers and drilling contractors that design production bores with intake screens. The tool calculates the water entrance velocity through the screen apperture given the screen technical specifications (diameter, lenght, blank space (e.g. wedge wire width), apperture opening size) and enable reconfiguration of the screen until the screen meets the design criteria that can be user specified or default.
Screen Entrance Velocity Calculation
Version
1.0.2.1
Date
02/07/2024
What's New
bottom of page